Related Experiment Video
Updated: Oct 1, 2025

A Murine Model of Hemodialysis Access-Related Hand Dysfunction
Published on: May 31, 2022
Weight-Based Assessment of Access Flow Threshold to Predict Arteriovenous Fistula Functional Patency
Chih-Yu Yang1,2,3,4,5,6, Bo-Sheng Wu1,2, Yi-Fang Wang3
1Institute of Clinical Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Introduction:
The 2019 Kidney Disease Outcome Quality Initiative (K/DOQI) guideline recommended evaluating arteriovenous fistula (AVF) malfunction risks primarily based on clinical monitoring, which can be assisted with the value of vascular access flow (Qa). Nevertheless, Qa thresholds recommended by different guidelines vary, ranging from 300 to 500 ml/min. This study investigated the optimal Qa threshold to predict future functional patency in AVFs with Qa <500 ml/min.
Methods:
Both the clinical indicators of access dysfunction and the Qa value were monitored in patients receiving hemodialysis by the radiocephalic AVF. Routine access flow surveillance was performed by the ultrasound dilution method (HD03, Transonic Inc.). The development of clinically significant indicators of access dysfunction, which necessitated percutaneous transluminal angiography (PTA) to maintain functional patency, was analyzed in this cohort.
Results:
Among the enrolled 302 patients, Qa of 52 patients was under 500 ml/min. These 52 patients received 2 Qa measurements during the follow-up period. Of these 52 patients, serial Qa of 17 patients varied trivially and their AVF remained functional. Multivariable logistic regression analysis revealed that a low Qa per ideal body weight (IBW) is an independent predictor of AVF functional loss. Receiver operating characteristic curve analysis of Qa/IBW in predicting future AVF functional loss revealed that the best cutoff value of Qa is 7.1 times the IBW.
Conclusion:
For radiocephalic AVFs with Qa <500 ml/min, the minimally required Qa to maintain access function is associated with individual IBW. The IBW-based Qa threshold assessment would allow more flexibility in the treatment of patients and reduce unnecessary invasive measures.
Related Concept Videos
Hemodialysis I: Introduction
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure

