Related Experiment Video
Updated: Oct 1, 2025

An Improved Method for Rapid Intubation of the Trachea in Mice
Published on: February 22, 2016
Intratracheal oxygen administration increases FIO2 and PaO2 compared with intranasal administration in healthy,
Objective:
To evaluate the efficacy of 2 different oxygen delivery strategies-intranasal and tracheal insufflation-on the inspired fraction of oxygen (FIO2) in standing horses and to determine the time needed for arterial oxygen partial pressure (PaO2) equilibration.
Animals:
6 healthy adult horses.
Procedures:
In this blinded, randomized crossover design study, horses were randomly assigned to receive oxygen via nasal cannula (group N) or transcutaneous tracheal catheter (group T). After placement of venous and arterial catheters, FIO2 was measured through a catheter placed into the distal portion of the trachea. After baseline measurements were obtained, horses received oxygen at up to 25 mL/kg/min for 1 hour via either intranasal or intratracheal catheter. The FIO2 and PaO2 were recorded at 5, 10, 15, 20, 25, 30, 45, and 60 minutes during and 5, 10, 15, 20, and 30 minutes after oxygen insufflation. Data were analyzed by use of a 2-way repeated measures ANOVA with Tukey-Kramer post hoc testing for pairwise comparisons (P < 0.05).
Results:
During oxygen administration, FIO2 and PaO2 increased significantly when compared with baseline, resulting in significantly higher values for group T (37.7 ± 2.4%; 214.6 ± 18 mm Hg) than for group N (34.3 ± 3.9%; 184.1 ± 11 mm Hg). The equilibration time was less than 10 minutes.
Clinical Relevance:
Intratracheal oxygen administration resulted in better oxygenation than nasal insufflation and should therefore be considered in standing horses that are experiencing severe respiratory compromise. The equilibration between FIO2 and PaO2 is rapid in adult horses.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...