Related Experiment Video
Updated: Oct 1, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Intra-breath changes in respiratory mechanics assessed from multi-frequency oscillometry measurements
Gergely Makan1, Ronald J Dandurand2,3, Zoltán Gingl1
1Department of Technical Informatics, University of Szeged, Szeged, Hungary.
Abstract:
Objective. Recent studies in respiratory system impedance (Zrs) with single-frequency oscillometry have demonstrated the utility of novel intra-breath measures of Zrs in the detection of pathological alterations in respiratory mechanics. In the present work, we addressed the feasibility of extracting intra-breath information from Zrs data sets obtained with conventional oscillometry.Approach. Multi-frequency recordings obtained in a pulmonology practice were re-analysed to track the 11 Hz component of Zrs during normal breathing and compare the intra-breath measures to that obtained with a single 10 Hz signal in the same subjects. A nonlinear model was employed to simulate changes in Zrs in the breathing cycle. The values of resistance (R) and reactance (X) at end expiration and end inspiration and their corresponding differences (ΔRand ΔX) were compared.Main results. All intra-breath measures exhibited similar mean values at 10 and 11 Hz in each subject; however, the variabilities were higher at 11 Hz, especially for ΔRand ΔX. The poorer quality of the 11 Hz data was primarily caused by the overlapping of modulation side lobes of adjacent oscillation frequencies. This cross-talk was enhanced by double breathing frequency components due to flow nonlinearities.Significance. Retrospective intra-breath assessment of large or special data bases of conventional oscillometry can be performed to better characterise respiratory mechanics in different populations and disease groups. The results also have implications in the optimum design of multiple-frequency oscillometry (avoidance of densely spaced frequencies) and the use of filtering procedures that preserve the intra-breath modulation information.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...

