PET in vivo generators 134Ce and 140Nd on an internalizing monoclonal antibody probe
G W Severin1,2,3, J Fonslet4,5, L K Kristensen6,5
1The Hevesy Laboratory, DTU Health Technology, Technical University of Denmark (DTU), Frederiksborgvej 399, 4000, Roskilde, Denmark. gwseverin@chemistry.msu.edu.
Abstract:
The in vivo-generator radionuclides 140Nd (t1/2 = 3.4 d) and 134Ce (t1/2 = 3.2 d) were used to trace a urokinase-type plasminogen activator (uPA)-targeting mouse monoclonal antibody, ATN-291, in U87 MG xenograft tumor-bearing mice. ATN-291 is known to internalize on the uPA/uPA-receptor pair, making it an appropriate targeting vector for investigating the fate of in vivo generator daughters on internalizing probes. Ante-mortem and post-mortem PET imaging at 120 h post-injection gave no indication of redistribution of the positron emitting daughter nuclides 134La and 140Pr from tumor tissue (p > 0.5). The lack of redistribution indicates that the parent radionuclides 134Ce and 140Nd could be considered as long-lived PET-diagnostic matches to therapeutic radionuclides like 177Lu, 161Tb and 225Ac when internalizing bioconjugates are employed.