Abstract:
In certain situations, internal insulation is the only possible renovation option. However, it is risky where there is high humidity in a building and ventilation is not working sufficiently. The internal insulation retrofit changes the original thermal and moisture balance of a wall, therefore, it is necessary to carefully design it already at the initial stage. This paper analyses four interior insulation systems based on open diffusion capillary active materials: wood fibreboards (flex and rigid), perlite boards, and microporous calcium silicate. The hygrothermal performance under the climatic conditions of Central Europe (Poland) was assessed using the WUFI Plus software, taking into account the dynamic variation of indoor and outdoor conditions. The analysis included three insulation thicknesses with different ventilation rates and varying moisture loads. The results show that the hygrothermal properties of the wall change with the increase of insulation thickness and depend on the individual moisture properties of the material. In addition, both the reduction of moisture load and more intensive air exchange improve the hygrothermal properties at the interface between the insulation and the wall. Of all the solutions analysed, the system with perlite board and the system with wood fibreboard showed the worst hygric properties. Conversely, the highest risk of mould and interstitial condensation was recorded for the flex wood fibreboard solution.
More Related Videos
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Insulation Coordination
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Heat Capacities of an Ideal Gas II
Calorimetry