Real-Time Internet of Medical Things System for Detecting Blood Leakage during Hemodialysis Using a Novel Multiple
Hsiang-Wei Hu1,2, Chih-Hao Liu3, Yi-Chun Du1,4
1Department of Biomedical Engineering, National Cheng Kung University, Tainan 704, Taiwan.
Abstract:
Venous needle dislodgement (VND) is a major healthcare safety concern in patients undergoing hemodialysis. Although VND is uncommon, it can be life-threatening. The main objective of this study was to implement a real-time multi-bed monitoring system for VND by combining a novel leakage-detection device and IoMT (Internet of Medical Things) technology. The core of the system, the Acusense IoMT platform, consisted of a novel leakage-detection patch comprised of multiple concentric rings to detect blood leakage and quantify the leaked volume. The performance of the leakage-detection system was evaluated on a prosthetic arm and clinical study. Patients with a high risk of blood leakage were recruited as candidates. The system was set up in a hospital, and the subjects were monitored for 2 months. During the pre-clinical simulation experiment, the system could detect blood leakage volumes from 0.3 to 0.9 mL. During the test of the IoMT system, the overall success rate of tests was 100%, with no lost data packets. A total of 701 dialysis sessions were analyzed, and the accuracy and sensitivity were 99.7% and 90.9%, respectively. Evaluation questionnaires showed that the use of the system after training changed attitudes and reduced worry of the nursing staff. Our results show the feasibility of using a novel detector combined with an IoMT system to automatically monitor multi-bed blood leakage. The innovative concentric-circle design could more precisely control the warning blood-leakage threshold in any direction to achieve clinical cost-effectiveness. The system reduced the load on medical staff and improved patient safety. In the future, it could also be applied to home hemodialysis for telemedicine during the era of COVID-19.
More Related Videos
04:52Dynamic Continuous Blood Extraction from Rat Heart via Noninvasive Microdialysis Technique
Published on: September 13, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hemodialysis III: Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Errors occurring during blood pressure monitoring
Several factors...