Related Experiment Video
Updated: Sep 30, 2025

Calcification of Vascular Smooth Muscle Cells and Imaging of Aortic Calcification and Inflammation
Published on: May 31, 2016
Automatic Measurement of Vascular Calcifications in Patients with Aorto-Iliac Occlusive Disease to Predict the Risk
Lucas Guidi1, Fabien Lareyre2, Arindam Chaudhuri3
1Department of Vascular Surgery, University Hospital of Nice, Nice, France.
Background:
There is currently a lack of consensus and tools to easily measure vascular calcification using computed tomography angiography (CTA). The aim of this study was to develop a fully automatic software to measure calcifications and to evaluate the interest as predictive factor in patients with aorto-iliac occlusive disease.
Methods:
This study retrospectively included 171 patients who had endovascular repair of an aorto-iliac occlusive lesion at the University Hospital of Nice between January 2011 and December 2019. Calcifications volumes were measured from CTA using an automatic method consisting in three sequential steps: image pre-processing, lumen segmentation using expert system, and deep learning algorithms and segmentation of calcifications. Calcification volumes were measured in the infrarenal abdominal aorta and the iliac arterial segments, corresponding to the common and the external iliac arteries.
Results:
Among 171 patients included with a mean age of 65 years, the revascularization was performed on the native external and internal iliac arteries in, respectively: 83 patients (48.5%), 107 (62.3%), and 7 (4.1%). The mean volumes of calcifications were 2,759 mm3 in the infrarenal abdominal aorta, 1,821 mm3 and 1,795 mm3 in the right and left iliac arteries, respectively. For a mean follow-up of 39 months, target lesion re-intervention was performed in 55 patients (32.2%). These patients had higher volume of calcifications in the right and left iliac arteries, compared with patients who did not have a re-intervention (2,274 mm3 vs. 1,606 mm3, P = 0.0319 and 2,278 vs. 1,567 mm3, P = 0.0213).
Conclusions:
The development of a fully automatic software would be useful to facilitate the measurement of vascular calcifications and possibly better inform the prognosis of patients.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
11:30A Semi-Automated and Reproducible Biological-Based Method to Quantify Calcium Deposition In Vitro
Published on: June 2, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies