Cardiac output monitoring - invasive and noninvasive
Virendra K Arya1, Waiel Al-Moustadi, Vikas Dutta
1Department of Anesthesiology, Perioperative and Pain Medicine, Max Rady College of Medicine, University of Manitoba, Winnipeg, MB, Canada.
Purpose Of Review:
The purpose of this article is to review various contemporary cardiac output (CO) measurement technologies available and their utility in critically ill patients.
Recent Findings:
CO measurement devices can be invasive, minimally invasive, or noninvasive depending upon their method of CO measurement. All devices have pros and cons, with pulmonary artery catheter (PAC) being the gold standard. The invasive techniques are more accurate; however, their invasiveness can cause more complications. The noninvasive devices predict CO via mathematical modeling with several assumptions and are thus prone to errors in clinical situations. Recently, PAC has made a comeback into clinical practice especially in cardiac intensive care units (ICUs). Critical care echocardiography (CCE) is an upcoming tool that not only provides CO but also helps in differential diagnosis. Lack of proper training and nonavailability of equipment are the main hindrances to the wide adoption of CCE.
Summary:
PAC thermodilution for CO measurement is still gold standard and most suitable in patients with cardiac pathology and with experienced user. CCE offers an alternative to thermodilution and is suitable for all ICUs; however, structural training is required.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...