Quantitative evaluation of aerosol generation from upper airway suctioning assessed during tracheal intubation and
A J Shrimpton1, J M Brown2, T M Cook3
1Anaesthesia, Pain and Critical Care, School of Physiology, Pharmacology and Neuroscience, University of Bristol, Bristol, UK.
Background:
Open respiratory suctioning is defined as an aerosol generating procedure (AGP). Laryngopharyngeal suctioning, used to clear secretions during anaesthesia, is widely managed as an AGP. However, it is uncertain whether upper airway suctioning should be designated as an AGP due to the lack of both aerosol and epidemiological evidence.
Aim:
To assess the relative risk of aerosol generation by upper airway suctioning during tracheal intubation and extubation in anaesthetized patients.
Methods:
This prospective environmental monitoring study was undertaken in an ultraclean operating theatre setting to assay aerosol concentrations during intubation and extubation sequences, including upper airway suctioning, for patients undergoing surgery (N=19). An optical particle sizer (particle size 0.3-10 μm) sampled aerosol 20 cm above the patient's mouth. Baseline recordings (background, tidal breathing and volitional coughs) were followed by intravenous induction of anaesthesia with neuromuscular blockade. Four periods of laryngopharyngeal suctioning were performed with a Yankauer sucker: pre-laryngoscopy, post-intubation, pre-extubation and post-extubation.
Findings:
Aerosol was reliably detected {median 65 [interquartile range (IQR) 39-259] particles/L} above background [median 4.8 (IQR 1-7) particles/L, P<0.0001] when sampling in close proximity to the patient's mouth during tidal breathing. Upper airway suctioning was associated with a much lower average aerosol concentration than breathing [median 6.0 (IQR 0-12) particles/L, P=0.0007], and was indistinguishable from background (P>0.99). Peak aerosol concentrations recorded during suctioning [median 45 (IQR 30-75) particles/L] were much lower than during volitional coughs [median 1520 (IQR 600-4363) particles/L, P<0.0001] and tidal breathing [median 540 (IQR 300-1826) particles/L, P<0.0001].
Conclusion:
Upper airway suctioning during airway management was not associated with a higher aerosol concentration compared with background, and was associated with a much lower aerosol concentration compared with breathing and coughing. Upper airway suctioning should not be designated as a high-risk AGP.
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....