Establishment and Evaluation of a Porcine Vein Graft Disease Model
Published on: July 25, 2022
Outcomes of Gore iliac branch endoprosthesis with internal iliac component versus Gore Viabahn VBX
Cole C Pickney1, Jarrad Rowse2, Jon Quatromoni2
1Department of Vascular Surgery, Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH; School of Medicine, Case Western Reserve University, Cleveland, OH.
Objective:
The Gore Excluder iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) is the only iliac branch device approved in the United States to preserve blood flow to the external and internal iliac arteries (IIAs). Some surgeons have used the Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associates) in the IIA rather than the self-expanding endograft designed for the IBE, the internal iliac component (IIC). The objective of the present study was to examine the outcomes for patients treated for aortoiliac artery aneurysms using the IBE with either the IIC or VBX stent.
Methods:
We performed a retrospective, single-center review of patients treated for aortoiliac artery aneurysms using the Gore IBE device, with either the IIC or VBX stent into the IIA, from February 2016 to March 2021. The patient demographics, procedure details, 30-day morbidity and mortality, and 6-month and 1-year outcomes and mortality were analyzed. The categorical factors are summarized using frequencies and proportions. Continuous measures are summarized as the mean ± standard deviation. A significance level of P = .05 was assumed for all test results. The analyses were performed using SAS software, version 9.4 (SAS Institute, Cary, NC).
Results:
A total of 62 patients (64 arteries) had undergone elective aortoiliac artery aneurysm repair with the IBE. The IIC was used exclusively in 35 cases (55%) and the VBX in 29 (45%). The patients who had received the VBX had had a higher American Society of Anesthesiologists class (P = .006). Upper extremity access was used for VBX delivery in 24.1% of the procedures. No return to the operating room was required in either group. No differences were found in technical success (IIC, 97.1%; VBX, 93.1%; P = .59), the presence of endoleak on completion (20.0% vs 6.9%; P = .17), readmission (97.1% vs 93.1%; P = .59), or mortality (1.6% vs 0%; P = .45) at 30 days. No differences were found in the requirement for any IBE reintervention after 30 days. No type Ia, Ib, or III endoleaks had occurred in either group at any follow-up point. No significant difference was found in internal iliac limb primary patency (IIC, 100%; VBX, 96.3%) between groups. A nonstatistically significant trend was found toward fewer trunk-ipsilateral leg type II endoleaks in the VBX group during follow-up.
Conclusions:
These data suggest that the VBX is a reasonable substitute for the IIC, with a comparable safety and efficacy profile. Given its inherent conformability, greater range of diameters, and longer working length, the VBX stent offers expanded IIA branch options with the IBE.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Related Concept Videos
Hemodialysis I: Introduction
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Aneurysm III: Interprofessional Care
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...