The diagnostic challenge of mild citrulline elevation at newborn screening
Barbara Siri1, Giorgia Olivieri2, Antonio Angeloni3
1Division of Metabolism, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy; Department of Paediatrics, Città della Salute e della Scienza, OIRM, Univerisity of Turin, Italy.
Abstract:
Citrulline is a target analyte measured at expanded newborn screening (NBS) and its elevation represents a biomarker for distal urea cycle disorders and citrin deficiency. Altered ratios of citrulline with other urea cycle-related amino acids are helpful for the differential diagnosis. However, the use of cut-off values in screening programmes has raised the issue about the interpretation of mild elevation of citrulline levels detected at NBS, below the usual range observed in the "classical/severe" forms of distal urea cycle disorders and in citrin deficiency. Herein, we report ten subjects with positive NBS for a mild elevation of citrulline (<100 μmol/L), in whom molecular investigations revealed carriers status for argininosuccinate synthase deficiency, a milder form of argininosuccinate lyase deficiency and two other diseases, lysinuric protein intolerance and dihydrolipoamide dehydrogenase deficiency, not primarily affecting the urea cycle. To guide the diagnostic process, we have designed an algorithm for mild citrulline elevation (<100 μmol/L) at NBS, which expands the list of disorders to be included in the differential diagnosis.
Related Concept Videos
Urea Cycle
Serum Studies: Renal Function Tests
Inborn Errors of Metabolism