A comparison of nonlinear extensions to the ensemble Kalman filter: Gaussian anamorphosis and two-step ensemble

Ian Grooms1

  • 1Department of Applied Mathematics, University of Colorado, Boulder, CO USA.

Computational Geosciences
|March 14, 2022
PubMed

Related Concept Videos

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
109
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model01:13

Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model

Drugs administered through various routes can lead to nonlinear elimination, resulting in complex pharmacokinetic behaviors crucial to understanding efficacious drug dosing.
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
131
Nonlinear Pharmacokinetics: Causes of Nonlinearity01:22

Nonlinear Pharmacokinetics: Causes of Nonlinearity

Nonlinearity in drug pharmacokinetics is caused by various factors influencing how a drug is absorbed, distributed, metabolized, and excreted. Understanding these nonlinear processes is crucial for predicting drug behavior in the body and optimizing drug dosing regimens.
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
375
Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
146
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
782
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
2.7K