Related Experiment Video
Updated: Sep 30, 2025

Establishment of a Robust and Reproducible Model of Radiation-Induced Skin and Muscle Fibrosis
Published on: August 31, 2022
UNWANTED RADIATION EXPOSURE TO RADIOSENSITIVE ORGANS DURING HAND CT
Dae Jin Nam1, Sun Rock Moon2, Hong Je Kang1
1Department of Orthopedic Surgery, Wonkwang University Hospital, Iksan, Republic of Korea.
Shielding significantly reduces radiation exposure to radiosensitive organs during hand computed tomography (CT) scans. This protective measure is crucial, especially for organs closer to the scan target, minimizing unwanted radiation dose.
Area of Science:
- Medical Imaging
- Radiology
- Radiation Protection
Background:
- Computed tomography (CT) scans, including multi-detector CT (MDCT) and cone-beam CT (CBCT), are valuable diagnostic tools.
- However, CT imaging poses a risk of unwanted radiation exposure to radiosensitive organs, particularly during extremity scans like those of the hand.
Purpose of the Study:
- To investigate radiation exposure levels in radiosensitive organs during hand CT scans.
- To evaluate the effectiveness of shielding in reducing this radiation exposure.
Main Methods:
- A prospective observational study involving patients undergoing hand CT scans.
- Patients were randomized to receive or not receive a radiation shield.
- Two imaging modalities, MDCT and cone-beam CT (CBCT), were used.
- Radiation doses were measured using thermoluminescent dosemeter chips on radiosensitive organs.
Main Results:
- Shielding significantly decreased radiation doses: a mean reduction of 79% in the MDCT group and 88.6% in the CBCT group.
- In non-shielded patients, radiation dose increased with proximity to the target area.
- The effectiveness of shielding was more pronounced for organs closer to the target point.
Conclusions:
- Radiation shielding is highly effective in reducing unwanted radiation exposure to radiosensitive organs during hand CT scans.
- Optimizing patient positioning to maximize distance between radiosensitive organs and the target area is recommended.
- Shielding is particularly important for radiosensitive organs located near the target area during CT imaging.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...