Related Experiment Video
Updated: Sep 30, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Establishing diagnostic reference levels for pediatric fluoroscopic examinations in a tertiary hospital
Yolanda E Gomes1, Gregory C Brown2, Josephine Davies3
1UniSA Allied Health and Human Performance Unit, University of South Australia, GPO Box 2471, City East Campus, SA, 5001, Adelaide, Australia. yolandaegomes@yahoo.com.
Background:
Diagnostic reference levels (DRLs) identify unusually high patient radiation exposures and are required for dose optimisation. DRLs for pediatric fluoroscopic examinations are not widely determined in Australia.
Objective:
Our objectives were to establish DRLs for pediatric fluoroscopic examinations in a South Australian tertiary hospital and compare these to previously published data and to explore relationships between patient dose area product (DAP), age and fluoroscopy times.
Materials And Methods:
Dose data from 365 pediatric patients undergoing 5 fluoroscopic examinations were retrospectively collected for a 3-year period commencing January 2018 to develop local DRLs. Relationships between DAP, age and fluoroscopy time were explored using scatterplots, Spearman's correlation, and regression analyses.
Results:
Local DRLs were significantly lower than data published previously, possibly reflecting technological and procedural advancements. Each 1-year increase in patient age was associated with a 0.77 μGy·m2 increase in DAP for barium meal and follow-through studies (95% confidence interval [CI]=0.055, 1.48) (P=0.04), and a 1.37 μGy·m2 increase in DAP for barium swallow studies (95% CI=0.61, 2.12) (P<0.001). A low correlation was demonstrated between DAP and fluoroscopy time for micturating cystourethrography studies (r=0.35, 95% CI=0.15, 0.51, P<0.001) and barium meal and follow-through studies (r=0.37, 95% CI= -0.011, 0.65, P=0.05). Age and fluoroscopy time were not significantly related.
Conclusion:
This study provides updated Australian pediatric fluoroscopic DRLs, with the intention of promoting a national database for benchmarking pediatric doses. The local DRLs can be used for dose comparisons and optimisation between facilities.
More Related Videos
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
15:18Making MR Imaging Child's Play - Pediatric Neuroimaging Protocol, Guidelines and Procedure
Published on: July 30, 2009
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...