Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
The association between office blood pressure and fluid status using bioimpedance spectroscopy in stable continuous
Adriaan Slabbert1, Mogamat-Yazied Chothia2
1Division of Nephrology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Cape Town, South Africa.
Background:
Hypertension is common in continuous ambulatory peritoneal dialysis (CAPD) patients. It remains to be determined the extent to which fluid overload contributes to uncontrolled blood pressure (BP) in this population. The aim was to determine the association between fluid status as measured using bioimpedance spectroscopy (BIS) and BP in CAPD patients.
Methods:
A cross-sectional study was performed involving 50 stable CAPD patients at a single center in Cape Town, South Africa. All participants were known to have hypertension and were divided into two groups based on office BP measurements: an uncontrolled BP group (systolic BP ≥ 140 mmHg or diastolic BP ≥ 90 mmHg) and a controlled BP group. Fluid status was determined using BIS (Body Composition Monitor®, Fresenius Medical Care, Bad Homburg, Germany).
Results:
There was a statistically significant difference in overhydration (OH) between the uncontrolled BP group and the controlled BP group (3.0 ± 2.3 L vs. 1.4 ± 1.6 L, respectively, P = 0.01). The uncontrolled BP group was older (37.7 ± 9.5 years vs. 32.0 ± 8.0 years, P = 0.04) and had a shorter dialysis vintage (15 [IQR, 7-22] months vs. 31 [IQR, 12-39] months, P = 0.02). Significant correlations were found between OH and the extracellular water (ECW) (r = 0.557, P < 0.01) and ECW to total body water (TBW) ratio (r = 0.474, P < 0.01). Mixed ancestry, presence of residual kidney function, ECW, and ECW to TBW ratio were identified as predictors of OH on multivariable linear regression.
Conclusions:
We found that stable CAPD patients with uncontrolled BP had higher OH compared to patients whose BP was controlled.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:36Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Hemodialysis III: Nursing Management
Peritoneal Dialysis III: Nursing Management