Airborne SARS-CoV-2 RNA excretion by patients with COVID-19 on different oxygen-delivery systems: a prospective
M L Janssen1, Y P Klazen2, P de Man3
1Department of Intensive Care, Franciscus Gasthuis & Vlietland, Rotterdam, the Netherlands; Department of Pulmonary Medicine, Erasmus MC, Rotterdam, the Netherlands; Department of Intensive Care, Erasmus MC, Rotterdam, the Netherlands.
Background:
Concerns persist regarding the risk of airborne SARS-CoV-2 transmission by patients with COVID-19 on various modalities of oxygen therapy, such as high-flow nasal cannula (HFNC).
Aim:
We aimed to compare the presence of airborne RNA in air samples between groups of patients with COVID-19 on different oxygen-delivery systems. We also explored factors that were associated with SARS-CoV-2 RNA positivity in air samples.
Results:
Air samples were positive for SARS-CoV-2 RNA in three of 39 patients (8%) on HFNC, 0 of 13 (0%) on masks, versus five of 20 (25%) on nasal cannula. Odds ratio for air sample positivity was 0.52 (95% confidence interval (CI) 0.11-2.34) when comparing HFNC vs non-HFNC group, and 5.78 (1.24-27.01) for nasal cannula vs non-nasal cannula group. Patients with positive air samples in comparison with those with negative air samples were sampled earlier after symptoms onset (median: 7 vs 10 days; P=0.04) and had lower Ct values of diagnostic nasopharyngeal samples (median: 22 vs 26; P=0.02).
Conclusions:
Air sample positivity was not related to oxygen support device but to viral load. These data suggest that the use of personal protection equipment should be based on risk management according to viral load rather than oxygen support device.
More Related Videos
07:13Swabbing the Urban Environment - A Pipeline for Sampling and Detection of SARS-CoV-2 From Environmental Reservoirs
Published on: April 9, 2021
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-III
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...