Related Experiment Video
Updated: Sep 30, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Agreement of the Apple Watch® and Fitbit Charge® for recording step count and heart rate when exercising in water
Nicholas J Held1,2,3, Andrew S Perrotta4, Tyler Mueller5
1School of Health Sciences, St. Lawrence College, Kingston, ON, Canada. nheld9@gmail.com.
Abstract:
This study examined the association and level of agreement between criterion methods and the Apple Watch 4® and Fitbit Charge 3® for recording step count and heart rate when exercising in water on an aquatic treadmill (ATM). Sixteen healthy participants (13 females and 3 males) volunteered to take part in this study. Participants were submerged in an ATM pool to the level of their xiphoid process and completed 3-min exercise bouts at intensities that corresponded to a comfortable walk, brisk walk, jog, and running. A Polar® T31 chest strap recorded heart rate (HR) and a high-definition digital camera was utilized for recording step count (SC). Significant associations (p < 0.001) were observed between criterion methods and the Apple® (HR: R2 = 0.99 and SC: R2 = 0.87) and Fitbit® (HR: R2 = 0.72 and SC: R2 = 0.83) devices. The mean absolute error and relative error (%) for recording step count were 19.8 (7.4%) in the Apple Watch and 21.4 (8.5%) in the Fitbit and 0.90 (0.76%) in the Apple Watch and 4.2 (3.0%) in the Fitbit for recording heart rate. Both devices displayed a reasonable level of agreement for recording step count and heart rate when exercising in water. Linear regression analysis demonstrating the association between each wearable device and the Apple Watch and Fit Bit Charge for recording step count and heart rate.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Assessment of blood pressure in brachial artery(two-step method)
Holter Monitor: 24-Hour Monitoring