Low Voltage Voltammetry Probes Proton Dissociation Equilibria of Amino Acids and Peptides

Sheng-Ping Liang1, Eloise Masquelier2, Daniel E Morse3,4

  • 1Department of Chemistry and Biochemistry, University of California, Santa Barbara, Santa Barbara, California 93106, United States.

Analytical Chemistry
|March 15, 2022
PubMed

Related Concept Videos

Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
535
Acid/Base Strengths and Dissociation Constants03:02

Acid/Base Strengths and Dissociation Constants

The relative strength of an acid or base is the extent to which it ionizes when dissolved in water. If the ionization reaction is essentially complete, the acid or base is termed strong; if relatively little ionization occurs, the acid or base is weak. There are many more weak acids and bases than strong ones. The most common strong acids and bases are listed below:
63.8K
Titration of a Weak Acid with a Weak Base01:08

Titration of a Weak Acid with a Weak Base

Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
3.5K
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
729
NMR Spectroscopy Of Amines01:19

NMR Spectroscopy Of Amines

In proton NMR spectroscopy, primary amines and secondary amines showcase their N–H protons as a broad signal in the chemical shift range between δ 0.5 and 5 ppm. The exact position in this range depends on several factors, including sample concentration, hydrogen bonding, and the type of solvent used. Since amine protons undergo fast proton exchange in solution, the protons are labile and therefore do not participate in any splitting with adjacent protons. Thus, the observed peak is...
9.5K
¹H NMR of Labile Protons: Temporal Resolution01:10

¹H NMR of Labile Protons: Temporal Resolution

Protons bonded to heteroatoms such as nitrogen and oxygen exhibit a range of chemical shift values. This is due to the varying degree of hydrogen bonding between the proton and the heteroatom in other molecules. The extent of hydrogen bonding affects the electron density around the proton, thereby giving different chemical shift values for the protons in the proton NMR spectrum.
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
1.3K