Related Experiment Video
Updated: Sep 30, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
A sensitive, robust method for determining natural and synthetic hormones in surface and wastewaters by continuous
Safae Chafi1, Evaristo Ballesteros2
1Department of Physical and Analytical Chemistry, E.P.S of Linares, University of Jaén, Avenida de La Universidad, 23700, Linares, Jaén, Spain.
Abstract:
Over recent decades, steroidal estrogens have become an emerging and very serious issue as they pose a serious threat to living organisms, soil, plants, and water resources in general. Estrogens have therefore been the subject of considerable scientific attention in order to develop new methodologies for its determination, being able of detecting them at very low concentrations. Those procedures minimize or eliminate the consumption of organic solvents and reagents that may be incompatible with the environment. In this respect, we developed a sensitive, selective method for the simultaneous determination of thirteen natural and synthetic hormones present at the nanogram-per-liter level in various types of water by using continuous solid-phase extraction in combination with gas chromatography and mass spectrometry (GC-MS). The target analytes were preferentially sorbed on an Oasis HLB sorbent column (80 mg) and eluted with acetone (600 µL) for derivatization with a mixture of 70 µL of N,O-bis(trimethylsilyl) trifluoroacetamide and trimethylchlorosilane and 35 µL of petroleum ether in a household microwave oven at 200 W for 4 min. Under optimum conditions, the ensuing method exhibited good linearity (r ≥ 0.998), good precision (RSD ≤ 7%), high recoveries (92-103%), and low detection limits (0.01-0.3 ng L-1). The method outperforms existing alternatives in robustness, sensitivity, throughput, flexibility-it allows both estrogens, progestogens, and androgens to be determined simultaneously-and compliance with the principles of Green Chemistry. It was successfully used to analyze various types of water samples (mineral, tap, well, pond, swimming pool, river, and waste) that were found to contain four estrogens (estrone, 17β-estradiol, 17α-ethinylestradiol, and hexestrol), two progestogens (testosterone, dihydrotestosterone), and one progestogen (progesterone) at concentrations ranging from 3.0 to 110 ng L-1.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...