Related Experiment Video
Updated: Sep 30, 2025

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Initial and 1-Year Radiographic Comparison of Reverse Total Shoulder Arthroplasty With a Short Versus Standard Length
Brandon J Erickson1, Patrick J Denard, Justin W Griffin
1From the Department of Orthopaedic Surgery, Sports Medicine and Shoulder, Rothman Orthopaedic Institute, New York, NY (Erickson), Southern Oregon Orthopedics, Medford, OR (Denard and Griffin), Jordan-Young Institute, Virginia Beach, VA, (Griffin) Cleveland Shoulder Institute, Beachwood, OH (Gobezie), University of Arizona College of Medicine-Phoenix, Phoenix, AZ (Lederman), and University of Virginia, Charlottesville, VA (Werner).
Introduction:
In an effort to preserve bone, humeral stems in reverse total shoulder arthroplasty (RTSA) have gradually decreased in length. The purpose of this study was to compare the immediate postoperative radiographic appearance of short-length with standard-length RTSA stems.
Methods:
Patients who underwent RTSA using a press-fit standard-length or short-length humeral implant with a consistent geometry (Univers Revers or Revers Apex) were evaluated in a multicenter retrospective review. Initial postoperative radiographs were used to assess initial alignment and filling ratios. In addition, radiographs were evaluated for early signs of stress shielding and/or loosening. Clinical outcome scores and range of motion were also evaluated.
Results:
Overall, 137 short-length stems and 139 standard-length stems were analyzed. Initial radiographs demonstrated a significantly higher percentage of stems placed in neutral alignment in the short-stem group (95.6% vs 89.2%, P = 0.045). Similar metaphyseal filling ratios were seen between groups, but a significantly higher diaphyseal filling ratio was observed in the short-stem group (57% vs 34%, P < 0.001). Less calcar osteolysis (2.2% vs 12.9%; P = 0.001) and fewer overall number of radiographic changes (tuberosity resorption, lucencies, and subsidence) (0.7% vs 5.0%; P = 0.033) were seen with short stems compared with the standard-length stems.
Conclusion:
RTSA with a short-stem humeral implant demonstrates excellent radiographic outcomes, including low rates of loosening and subsidence at 1 year, with less early calcar osteolysis compared with a standard-length stem.
Level Of Evidence:
III (Case-control).
More Related Videos
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022