Related Experiment Video
Updated: Sep 30, 2025

Determination of the Settling Rate of Clay/Cyanobacterial Floccules
Published on: June 11, 2018
New insights into real-time detection of tephra grainsize, settling velocity and sedimentation rate
V Freret-Lorgeril1, C Bonadonna2, E Rossi2
1Department of Earth Sciences, University of Geneva, 13, Rue des Maraichers, CH-1205, Geneva, Switzerland. valentin.freret-lorgeril@unige.ch.
Abstract:
Characterizing the size and settling velocity of pyroclastic fragments injected into the atmosphere during volcanic eruptions (i.e., tephra) is crucial to the forecasting of plume and cloud dispersal. Optical disdrometers have been integrated into volcano monitoring networks worldwide in order to best constrain these parameters in real time. Nonetheless, their accuracy during tephra fallout still needs to be assessed. A significant complication is the occurrence of particle aggregates that modify size and velocity distributions of falling tephra. We made the first use of the Thies Clima Laser Precipitation Monitor (LPM) for tephra-fallout detection at Sakurajima volcano (Japan), which is characterized by a lower size detection window with respect to more commonly used disdrometers (e.g., Parsivel2) and can more easily distinguish different falling objects. For the first time, individual particles have been distinguished from most aggregates based on disdrometer data, with the potential to provide useful grain-size information in real time. In case of negligible aggregation, LPM and collected sample-based estimates are in agreement for both grain-size and sedimentation rate. In case of significant aggregation, particle shape analyses and a dedicated drag equation are used to filter out aggregates from LPM data that also provide good agreement with collected tephra samples.
Related Concept Videos
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

