Related Experiment Video
Updated: Sep 29, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Accuracy of retention model parameters obtained from retention data in liquid chromatography
Tyler Brau1, Bob Pirok1,2, Sarah Rutan3
1Department of Chemistry, Gustavus Adolphus College, 800 West College Avenue, Saint Peter, MN, 56082, USA.
Abstract:
In liquid chromatography, it is often very useful to have an accurate model of the retention factor, k, over a wide range of isocratic elution conditions. In principle, the parameters of a retention model can be obtained by fitting either isocratic or gradient retention factor data. However, in spite of many of our own attempts to accurately predict isocratic k values using retention models trained with gradient retention data, this has not worked in our hands. In the present study, we have used synthetic isocratic and gradient retention data for small molecules under reversed-phase liquid chromatography conditions. This allows us to discover challenges associated with predicting isocratic k values without the confounding influences of experimental issues that are difficult to model or eliminate. The results indicate that it is not currently possible to consistently predict isocratic retention factors for small molecules with accuracies better than 10%, even when using synthetic gradient retention data. Two distinct challenges in fitting gradient retention data were identified: 1) a lack of 'uniqueness' in the parameters and 2) an inability to find the global optimum fit in a complex fitting landscape. Working with experimental data where measurement noise is unavoidable will only make the accuracy worse.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Related Concept Videos
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Analyte Adsorption and Distribution