Related Experiment Video
Updated: Sep 29, 2025

Basic Methods for the Study of Reproductive Ecology of Fish in Aquaria
Published on: July 20, 2017
Is more complex safer in the case of bail-out rebreathers for extended range cave diving?
Derek B Covington1,2,3, Charlotte Sadler4,5, Anthony Bielawski4,5
1Department of Anesthesiology, Duke University, Durham (NC), USA.
Abstract:
Nowhere is redundancy more indispensable than extended range cave diving. Training and practice in this discipline ensure divers are equipped with backup regulators, gauges, lights, and adequate breathing gas for a safe exit, emergencies, and decompression. Depending on penetration distances and depth, open circuit cave diving may require carrying more gas cylinders than can be logistically managed by the diver themselves while maintaining safe gas supply margins. Consequently, divers are forced to either stage cylinders in the cave prior to the dive or rely on resupply from support divers. Both scenarios have significant drawbacks. Due to the improved efficiency of breathing gas utilisation and other advantages, closed circuit rebreathers (CCR) have enabled extended range cave diving. With increasing depths, penetration distances, and bottom times, these divers must also plan for an increasing amount of open circuit bail-out gas in the event of CCR failure. Staged cylinders have traditionally been utilised, but this strategy has limitations due to the advanced dives needed to place them and equipment degradation due to prolonged water immersion, which can often result in cylinder and regulator corrosion with consequent leakage of contents over time. Consequently, a growing number of CCR divers are foregoing open-circuit bailout altogether by carrying an additional CCR system for bailout. Although these bailout rebreathers may facilitate further exploration and have certain advantages, the risks of diving with two complex machines remain to be clearly defined.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Buoyancy and Stability for Submerged and Floating Bodies
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Buoyancy

