To aspirate or not to aspirate? Considerations for the COVID-19 vaccines
Piotr Rzymski1,2, Andrzej Fal3
1Department of Environmental Medicine, Poznan University of Medical Sciences, 60-806, Poznan, Poland. rzymskipiotr@ump.edu.pl.
Abstract:
Syringe aspiration when vaccinating intramuscularly was not recommended before the pandemic due to the lack of conclusive evidence that it provides any benefit. However, in vivo evidence suggests that intravenous injection of mRNA vaccine can potentially lead to myocarditis, while introducing adenoviral vector to bloodstream can possibly result in thrombocytopenia and coagulopathy. These rare reactions were recorded in humans following the administration of the COVID-19 vaccines. Although the syringe aspiration may increase the level of pain at the injection site, it represents a simple technique to decrease the risk of vaccine introduction into the vascular system and potentially decrease the risk of severe reactions to mRNA and adenoviral vaccines. We are of the opinion that this cannot be disregarded if one considers that the COVID-19 vaccines will continue to be administrated globally in the form of initial and booster doses. Therefore, the aspiration when giving mRNA and adenoviral vaccines appears to be fully in line with the precautionary principle.
Insights
Syringe aspiration during intramuscular vaccination may prevent rare but severe reactions like myocarditis and thrombocytopenia from mRNA and adenoviral COVID-19 vaccines. This simple technique aligns with the precautionary principle for ongoing global vaccine administration.
Area of Science:
- Immunology
- Vaccinology
- Public Health
Background:
- Intramuscular vaccination guidelines previously did not recommend syringe aspiration due to insufficient evidence of benefit.
- Emerging in vivo data suggest potential risks associated with accidental intravascular administration of vaccines.
- Rare adverse events, including myocarditis (mRNA vaccines) and thrombocytopenia/coagulopathy (adenoviral vector vaccines), have been reported post-COVID-19 vaccination.
Purpose of the Study:
- To evaluate the potential benefit of syringe aspiration in reducing the risk of severe adverse reactions following COVID-19 vaccination.
- To assess the applicability of syringe aspiration in the context of ongoing global vaccine administration, including booster doses.
Main Methods:
- Review of in vivo evidence regarding vaccine administration routes and associated risks.
- Analysis of reported rare adverse events following COVID-19 vaccination.
- Consideration of the precautionary principle in vaccination techniques.
Main Results:
- Intravenous injection of mRNA vaccines may be linked to myocarditis.
- Intravascular administration of adenoviral vector vaccines may be associated with thrombocytopenia and coagulopathy.
- Syringe aspiration is a simple technique that can potentially mitigate the risk of accidental intravascular vaccine injection.
Conclusions:
- Syringe aspiration, despite potentially increasing local pain, offers a method to decrease the risk of intravascular vaccine introduction.
- The potential to reduce severe reactions makes syringe aspiration a relevant consideration for mRNA and adenoviral COVID-19 vaccines.
- Implementing syringe aspiration aligns with the precautionary principle for widespread vaccine administration, including boosters.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning II: Procedure