Cerebrovascular disease: evaluation with transbrachial intraarterial digital subtraction angiography using a 4-F

Radiology
|November 1, 1986
PubMed

Insights

This study shows that using smaller 4-F catheters for transbrachial digital subtraction angiography in carotid artery disease is effective and safe, with fewer complications than larger catheters.

Area of Science:

  • Vascular Surgery
  • Interventional Radiology
  • Diagnostic Imaging

Background:

  • Occlusive vascular disease of the carotid arteries poses a significant risk of stroke.
  • Intraarterial digital subtraction angiography (DSA) is a key diagnostic tool for evaluating carotid artery disease.
  • Minimizing procedural complications is crucial for patient safety and widespread adoption of diagnostic techniques.

Purpose of the Study:

  • To evaluate the efficacy and safety of using 65-cm-long, 4-F aortic catheters for transbrachial intraarterial digital subtraction angiography (DSA) in patients with carotid artery disease.
  • To compare complication rates with previous transbrachial series using larger (6-8-F) catheters.

Main Methods:

  • A retrospective analysis of 361 patients who underwent transbrachial DSA for definite or probable occlusive vascular disease of the carotid arteries.
  • Utilized 65-cm-long, 4-F aortic catheters for the procedure.
  • Assessed image quality and complication rates, including neurologic deficits, hematomas, and pulse deficits.

Main Results:

  • Excellent or good image quality was achieved in nearly all cases.
  • No postprocedural neurologic deficits or hematomas were reported.
  • A low incidence of permanent pulse deficit (2 patients) and temporary pulse deficit (3 patients) was observed.
  • Complication rates were lower compared to previous studies using larger catheters.

Conclusions:

  • Transbrachial DSA with 65-cm-long, 4-F aortic catheters is an effective and safe imaging technique for carotid artery disease.
  • This technique demonstrates improved safety outcomes, particularly reduced pulse deficits, compared to larger catheter use.
  • The study suggests a potential difference in relative safety between men and women, warranting further investigation.