Related Experiment Video
Updated: Sep 29, 2025

Fruit Volatile Analysis Using an Electronic Nose
Published on: March 30, 2012
Rapid detection and quantification of the adulteration of orange juice with grapefruit juice using handheld Raman
Mehrvash Varnasseri1, Yun Xu1, Royston Goodacre1
1Department of Biochemistry and Systems Biology, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, L69 7ZB, UK. Roy.Goodacre@liverpool.ac.uk.
Abstract:
Detecting food adulteration has always been an important task for food safety, especially when grapefruit is the adulterant as components in the juice have undesired interactions with many medicines. In this study we employed a handheld Raman device to detect adulteration of orange juices with grapefruit juices. Fresh fruits of orange and grapefruit were purchased from five different sources and fruit juices were made using a handheld juicer. The extracted juices were then mixed in a way that concentrations of grapefruit juices varied from 0% to 100% in 5% increments. In order to study the impact of the different sources of the fruits, three different sets of mixtures were prepared based on their spectral similarity and dissimilarity. Raman spectra were collected using a handheld instrument with an excitation laser at 785 nm and data analysed using principal component analysis (PCA), principal component-discriminant function analysis (PC-DFA) and partial least squares regression (PLS-R). PLS-R models were trained and validated on: (i) the full data set from the three different mixture sets, and (ii) each set of the three mixtures separately. The results showed that a good calibration model was obtained using full data which had a coefficient of determination (Q2) of 0.81 and a root mean square error of prediction (RMSEP) of 12.5%. Such results were improved when the PLS-R model was trained and validated on the three separate mixture combinations, where the Q2 varied from 0.85 to 0.89 and RMSEP varied from 9.9% to 11.6%. Finally, we adopted a two step approach in which a partial least squares for discriminant analysis (PLS-DA) was trained first to classify the three sample sources and then three different PLS-R models were subsequently trained on samples from the same source. This resulted in a Q2 of 0.83 and RMSEP of 12.0%. In conclusion, we have demonstrated that Raman spectroscopy can be used as a portable and rapid analytical tool for detecting adulteration of grapefruit juice added to orange juice.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
07:10Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
Published on: November 9, 2018
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Spectroscopy of Carboxylic Acid Derivatives
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
IR and UV–Vis Spectroscopy of Aldehydes and Ketones