Related Experiment Video
Updated: Sep 29, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Continuous VOCs Monitoring in Saturated and Unsaturated Zones Using Thermal Desorber and Gas Chromatography: System
Jinsung An1, Dong-Jun Baek1, Jiseok Hong2
1Department of Biological and Environmental Engineering, Semyung University, Jecheon-si 27136, Korea.
Abstract:
Subsurface VOC monitoring has been mainly based on manual sampling, transport, and analysis, which would require a sufficient amount of samples to ensure data accuracy and reliability, and additional costs to ensure sample quality. Therefore, a continuous on-site monitoring system is desirable for accurate measurement and subsequent risk assessment. In this study, benzene, toluene, ethylbenzene, and xylene (BTEX) were continuously monitored by the system based on a thermal desorber (TD) and gas chromatography (GC) in an oil-contaminated site that consisted of saturated and unsaturated zones. For the saturated zone, fully automated groundwater sampling and purging processes were performed, and the gasified samples were applied to the TD-GC system. For the unsaturated zone, the gaseous sample in the site was directly applied to the TD-GC system. After verifying the accuracy and precision of the monitoring system, the continuous monitoring system was successfully operated for more than a month in the field. The monitoring system used in this study is applicable to other sites for continuous monitoring, thus providing a scientific background for advanced risk assessment and policy development.
More Related Videos
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....

