Related Experiment Video
Updated: Jul 6, 2026

09:29
Utilization of Plasmonic and Photonic Crystal Nanostructures for Enhanced Micro- and Nanoparticle Manipulation
Published on: September 27, 2011
Author Correction: Enhancement of and interference among higher order multipole transitions in molecules near a
Evgenia Rusak1, Jakob Straubel1, Piotr Gładysz2
1Institute of Theoretical Solid State Physics, Karlsruhe Institute of Technology, 76131, Karlsruhe, Germany.
Nature Communications
|March 25, 2022
Abstract
No abstract available in PubMed .
Related Concept Videos
The Antenna Complex
Plants and other photosynthetic organisms comprise pigments capable of absorption of direct sunlight. These pigments are present in the reaction center - the main site of photochemical reactions as well as in the antenna complex. Under average light conditions, the rate at which reaction center pigments absorb light is far below the electron transport chain's capacity. As a result, the reaction center alone cannot provide enough energy to drive photosynthesis. The photosynthetic efficiency can...
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
π Electron Effects on Chemical Shift: Overview
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0, resulting in...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...

