Related Experiment Video
Updated: Sep 29, 2025

Evaluation of the Interplay Between the Complement Protein C1q and Hyaluronic Acid in Promoting Cell Adhesion
Published on: June 15, 2019
Complement C1q in plasma induces nonspecific binding of poly(acrylic acid)-coated upconverting nanoparticle antibody
Saara Kuusinen1, Miikka Ekman2, Kirsti Raiko2
1Department of Life Technologies, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520, Turku, Finland. saevku@utu.fi.
Abstract:
Upconverting nanoparticles are attractive reporters for immunoassays, because their high specific activity and lack of autofluorescence background enable their detection at extremely low concentrations. However, the sensitivity achieved with heterogeneous sandwich immunoassays using nanoparticle reporters is generally limited by the nonspecific binding of nanoparticle antibody conjugates to solid supports. In this study, we characterized plasma components associated with elevated nonspecific binding of poly(acrylic acid)-coated upconverting nanoparticles in heterogeneous two-step sandwich immunoassays. Plasma was consecutively fractionated using various chromatographic methods by selecting after each step the fractions producing the highest nonspecific binding of upconverting nanoparticle conjugates in an immunoassay for cardiac troponin I. Finally, the proteins in the fractions associated with highest amount of nonspecific binding were separated by gel electrophoresis and identified with mass spectrometry. The results indicated that complement component C1q was present in the fractions associated with the highest signal from nonspecific binding. The interference was not limited to only poly(acrylic acid)-coated nanoparticles or certain antibody combination, but occurred more generally. The interference was removed by increasing the ionic strength of the assay buffer in the sample incubation step or by adding a negatively charged blocker to bind on positively charged C1q, suggesting that the interaction is mostly electrostatic. Hence, we assume that the interference is likely to affect various negatively charged nanoparticles. The identification of complement component C1q as the major interfering protein allows for more rational design of countermeasures in future immunoassay development utilizing nanoparticle reporters.
Related Concept Videos
Antibody Actions
Neutralization
Antibodies can bind to pathogens, preventing them from infecting host cells. This process...
Complement System

