Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

1.1K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of Load on Quartz Crystal Microbalance Sensor Response Addressed Using Fractional Order Calculus.

Sensors (Basel, Switzerland)·2023
Same author

Spurious Resonance of the QCM Sensor: Load Analysis Based on Impedance Spectroscopy.

Sensors (Basel, Switzerland)·2023
Same author

Virtual Quartz Crystal Microbalance: Bioinspired Resonant Frequency Tracking.

Biomimetics (Basel, Switzerland)·2022
Same author

Quartz Crystal Microbalance with Impedance Analysis Based on Virtual Instruments: Experimental Study.

Sensors (Basel, Switzerland)·2022

Related Experiment Video

Updated: Sep 29, 2025

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
08:21

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics

Published on: January 22, 2020

13.7K

Advanced Impedance Spectroscopy for QCM Sensor in Liquid Medium.

Ioan Burda1

  • 1Physics Department, Babes-Bolyai University, 400084 Cluj-Napoca, Romania.

Sensors (Basel, Switzerland)
|March 26, 2022
PubMed
Summary
This summary is machine-generated.

Advanced impedance spectroscopy enhances quartz crystal microbalance (QCM) sensor analysis in liquids. New software methods improve measurement accuracy for mass and physical parameters.

Keywords:
QCM sensorsimpedance analysisin-liquid measurementspiezoelectric materialsvirtual instrumentation

More Related Videos

Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator
07:11

Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator

Published on: November 1, 2018

7.2K
Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5
09:46

Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5

Published on: August 25, 2016

11.8K

Related Experiment Videos

Last Updated: Sep 29, 2025

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
08:21

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics

Published on: January 22, 2020

13.7K
Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator
07:11

Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator

Published on: November 1, 2018

7.2K
Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5
09:46

Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5

Published on: August 25, 2016

11.8K

Area of Science:

  • Electrical Engineering
  • Materials Science
  • Analytical Chemistry

Background:

  • Impedance analysis offers precise electrical parameter measurement for Quartz Crystal Microbalance (QCM) sensors.
  • QCM sensors, through parameters like dissipation factor, enable detailed analysis of sample mass and physical properties.
  • Liquid medium immersion presents challenges for accurate QCM sensor analysis.

Purpose of the Study:

  • To demonstrate the advantages of advanced impedance spectroscopy using the Butterworth-van Dyke (BVD) model for QCM sensors in liquid.
  • To showcase the capabilities of a software-defined virtual impedance analyzer (VIA) for real-time QCM analysis.
  • To highlight improvements in QCM sensor characterization through advanced software methods.

Main Methods:

  • Utilized a fast, accurate software-defined virtual impedance analyzer (VIA) for real-time QCM electric model computation.
  • Implemented advanced software techniques including self-calibration, real-time compensation, and post-compensation.
  • Employed simultaneous calculation by multiple methods for robust analysis.

Main Results:

  • Experimental results validated theoretical concepts of impedance spectroscopy for QCM sensors.
  • Demonstrated the effectiveness of the VIA instrument for QCM analysis in liquid media.
  • Quantified significant improvements in impedance spectroscopy analysis accuracy using advanced software methods with the BVD model.

Conclusions:

  • Advanced impedance spectroscopy, particularly with the BVD model, significantly enhances QCM sensor performance in liquid.
  • The VIA instrument and associated advanced software methods provide a powerful tool for precise QCM characterization.
  • This approach offers improved accuracy for determining sample mass per unit area and physical parameters.