Related Experiment Video
Updated: Sep 29, 2025

Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Cardiac assessment accuracy by students using palm-held ultrasound compared to physical examination by skilled
Shirley Sarig1, Tsafrir Or1,2, Gassan Moady1,2
1Azrieli Faculty of Medicine in the Galilee, Bar-Ilan University, Safed, Israel.
Background:
Despite the inherent limitations of the traditional cardiac physical examination (PE), it has not yet been replaced by a more accurate method.
Methods:
We hypothesized that a single medical student, following a brief training (two academic hours) with the PHU, will better identify abnormal findings including significant valvular diseases, pericardial effusion and reduced LV function, as compared to PE performed by senior cardiologists and cardiology fellows. Transthoracic echocardiogram (TTE) served as a 'gold standard'.
Results:
Seventy-seven patients underwent TTE, of them 64 had an abnormal finding. PE identified 34 patients with an abnormal finding compared to 52 identified by PHU (p < 0.05). Ejection fraction (EF) below 50% was found in 35 patients on TTE, compared to only 15 and 6 patients by PE and PHU, respectively (p < 0.05). There was no difference in valvular dysfunction diagnosis detected by PE and medical students using PHU. The overall accuracy of PHU compared to TTE was 87%, with a specificity of 94% and sensitivity of 64% (the low sensitivity was driven mainly by EF assessment), whereas the accuracy of PE was 91%, specificity 91% and sensitivity 38% (again driven by poor EF assessment).
Conclusions:
Cardiac evaluation using PHU by a single medical student was able to demonstrate similar accuracy as PE done by cardiac specialists or cardiology fellows. The study topic should be validated in future studies with more medical students with a very brief training of cardiac ultrasound.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.