Noninvasive estimation of aortic pressure waveform based on simplified Kalman filter and dual peripheral artery
Wenyan Liu1, Shuo Du1, Shuran Zhou1
1College of Medicine and Biological and Information Engineering, Northeastern University, Shenyang 110169, China.
Background And Objective:
Aortic pressure (Pa) is important for the diagnosis of cardiovascular disease. However, its direct measurement is invasive, not risk-free, and relatively costly. In this paper, a new simplified Kalman filter (SKF) algorithm is employed for the reconstruction of the Pa waveform using dual peripheral artery pressure waveforms.
Methods:
Pa waveforms obtained in a previous study were collected from 25 patients. Simultaneously, radial and femoral pressure waveforms were generated from two simulation experiments, using transfer functions. In the first, the transfer function is a known finite impulse response; and in the second, it is derived from a tube-load model. To analyze the performance of the proposed SKF algorithm, variable amounts of noise were added to the observed output signal, to give a range of signal-to-noise ratios (SNRs). Additionally, central aortic, brachial and femoral pressure waveforms were simultaneously collected from 2 Sprague-Dawley rats and the measured and reconstructed Pa waveforms were compared.
Results:
The proposed SKF algorithm outperforms canonical correlation analysis (CCA), which is the current state-of-the-art blind system identification method for the non-invasive estimation of central aortic blood pressure. It is also shown that the proposed SKF algorithm is more noise-tolerant than the CCA algorithm over a wide range of SNRs.
Conclusion:
The simulations and animal experiments illustrate that the proposed SKF algorithm is accurate and stable in the face of low SNRs. Improved methods for estimating central blood pressure as a measure of cardiac load adds to their value as a prognostic and diagnostic tool.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.