Related Experiment Video
Updated: Sep 29, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Dental Strain on Maxillary Incisors During Tracheal Intubation With Double-Lumen Tubes and Different Laryngoscopy
Jerome Defosse1, Joris Kleinschmidt2, Axel Schmutz3
1University Witten/Herdecke, Medical Centre Cologne-Merheim, Department of Anaesthesiology and Intensive Care Medicine, Cologne, Germany.
Objectives:
To quantify dental forces during double-lumen tube intubations with different laryngoscopy techniques.
Design:
Experimental biomechanical mannequin study.
Setting:
Two German university hospitals.
Participants:
One hundred four anesthesiologists with varying levels of experience.
Interventions:
Participants performed a sequence of intubations on a mannequin equipped with hidden forces sensors in the maxillary incisors. Different laryngoscopy techniques were evaluated under normal and difficult airway conditions. Direct laryngoscopy was compared with different videolaryngoscopy techniques: the C-MAC with a Macintosh blade, the GlideScope, and the KingVision with hyperangulated blades.
Measurements And Main Results:
A total of 624 intubations were evaluated. In normal airway conditions, the median (interquartile range [range]) peak forces were significantly lower when the GlideScope (15.7 (11.3-22.0 [2.1-110.5]) N) was used compared with direct laryngoscopy (21.0 (14.1-28.5[4.7-168.6]) N) (p = 0.007). In difficult airways, resulting forces were reduced using hyperangulated videolaryngoscopes (GlideScope: -13.7 N [p < 0.001]; KingVision: -11.9 N [p < 0.001]) compared with direct laryngoscopy, respectively. The time to intubation was prolonged with the use of the KingVision (25.5 (17.1-41.9[9.2-275.0])s [p < 0.001]) in comparison to direct laryngoscopy (20.8 (15.9-27.4[8.7-198.6]) s). The C-MAC demonstrated the shortest time to intubation.
Conclusions:
Although hyperangulated videolaryngoscopes improve dental strain, clinicians also should consider the time to intubation, which is shortest with nonhyperangulated videoblades, when choosing a laryngoscopy technique on an individual patient basis.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation II: ACLS Airway Management