Related Experiment Video
Updated: Jul 23, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Proof-of-concept of DosiTest: A virtual multicentric clinical trial for assessing uncertainties in molecular
G Kayal1, N Clayton2, A Vergara-Gil2
1CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France; SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol 2400, Belgium.
Abstract:
Clinical dosimetry in molecular radiotherapy (MRT) is a multi-step procedure, prone to uncertainties at every stage of the dosimetric workflow. These are difficult to assess, especially as some are complex or even impossible to measure experimentally. The DosiTest project was initiated to assess the variability associated with clinical dosimetry, by setting up a 'virtual' multicentric clinical dosimetry trial based on Monte Carlo (MC) modelling. A reference patient model with a realistic geometry and activity input for a specific tracer is considered. Reference absorbed dose rate distribution maps are generated at various time-points from MC modelling, combining precise information on density and activity distributions (voxel wise). Then, centre-specific calibration and patient SPECT/CT datasets are modelled, on which the clinical centres can perform clinical (i.e. image-based) dosimetry. The results of this dosimetric analysis can be benchmarked against the reference dosimetry to assess the variability induced by implementing different clinical dosimetry approaches. The feasibility of DosiTest is presented here for a clinical situation of therapeutic administration of 177Lu-DOTATATE (Lutathera®) peptide receptor radionuclide therapy (PRRT). From a real patient dataset composed of 5 SPECT/CT images and associated calibrations, we generated the reference absorbed dose rate images with GATE. Then, simulated SPECT/CT image generation based on GATE was performed, both for a calibration phantom and virtual patient images. Based on this simulated dataset, image-based dosimetry could be performed, and compared with reference dosimetry. The good agreement, between real and simulated images, and between reference and image-based dosimetry established the proof of concept of DosiTest.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...