Related Experiment Video
Updated: Sep 28, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Minimizing the COVID-19 spread in hospitals through optimization of ventilation systems
Hamed Arjmandi1, Reza Amini1, Mehdi Kashfi1
1MR CFD LLC. No 49, Gakhokidze Street, Isani-Samgori District, Tbilisi 0182, Georgia.
Abstract:
The rapid spread of SARS-CoV-2 virus has overwhelmed hospitals with patients in need of intensive care, which is often limited in capacity and is generally reserved for patients with critical conditions. This has led to higher chances of infection being spread to non-COVID-19 patients and healthcare workers and an overall increased probability of cross contamination. The effects of design parameters on the performance of ventilation systems to control the spread of airborne particles in intensive care units are studied numerically. Four different cases are considered, and the spread of particles is studied. Two new criteria for the ventilation system-viz., dimensionless timescale and extraction timescale-are introduced and their performances are compared. Furthermore, an optimization process is performed to understand the effects of design variables (inlet width, velocity, and temperature) on the thermal comfort conditions (predicted mean vote, percentage of people dissatisfied, and air change effectiveness) according to suggested standard values and the relations for calculating these parameters based on the design variables are proposed. Desirability functions that are comprised of all three thermal condition parameters are used to determine the range of variables that result in thermally comfortable conditions and a maximum desirability of 0.865 is obtained. The results show that a poorly designed ventilation system acts like a perfectly stirred reactor-which enormously increases the possibilities of contamination-and that when air is injected from the ceiling and extracted from behind the patient beds, the infection spread is least probable since the particles exit the room orders of magnitude faster.
More Related Videos
09:03Nasal Brushing Sampling and Processing Using Digital High Speed Ciliary Videomicroscopy – Adaptation for the COVID-19 Pandemic
Published on: November 7, 2020
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings