MRI sequences and interslice gap influence leptomeningeal metastasis detection in children with brain tumors

Julie H Harreld1,2,3, Ayaz Khan4, Jacqueline Angel1

  • 1Department of Diagnostic Imaging, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Mail Stop 220, Memphis, TN, 38015, USA.

Neuroradiology
|March 28, 2022
PubMed
Abstract

Insights

Accurate MRI detection of leptomeningeal metastasis (LM) in children with brain tumors is improved by using specific technical factors. Smaller gaps between slices and T2 FLAIR with contrast enhance brain LM detection.

Area of Science:

  • Pediatric Neuro-oncology
  • Medical Imaging
  • Radiology

Background:

  • Accurate detection of leptomeningeal metastasis (LM) is crucial for managing pediatric brain tumors.
  • Poor-quality staging MRIs are linked to reduced survival in children with brain tumors.
  • Technical factors influencing MRI quality for LM detection are not well-defined.

Purpose of the Study:

  • To identify key technical factors associated with accurate MRI diagnosis of LM in pediatric brain tumor patients.
  • To determine if specific MRI acquisition parameters improve LM detection rates.

Main Methods:

  • Retrospective analysis of 75 pediatric patients with leptomeningeal seeding brain tumors.
  • Comparison of MRIs from outside facilities and institutional re-scans within 35 days.
  • Assessment of technical factors including slice thickness, gap, contrast use, and acquisition planes for brain and spine.

Main Results:

  • Smaller interslice gaps in brain and spine MRIs significantly increased LM detection rates.
  • Use of T2 FLAIR with contrast and sagittal plane for 3DT1WI in brain improved detection.
  • Employing alternatives to axial TSE/FSE for spine imaging also enhanced LM detection.

Conclusions:

  • Optimizing MRI technical factors can improve leptomeningeal metastasis detection in pediatric brain tumors.
  • Specific sequences (T2 FLAIR, sagittal 3DT1) and minimal interslice gaps are recommended for brain imaging.
  • Avoiding axial TSE/FSE sequences for spine imaging may aid LM diagnosis in this population.