Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Multimodal Haptic Feedback Interface with Thin-Film Compliant Mechanism.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Large language model chatbots as sources of pediatric anesthesia health advice: An evaluation of reliability and readability.

Digital health·2026
Same author

Steady-State and Dynamic Behavior of Geometry-Tunable Microfluidic Passive Flow Regulators.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Using GeoAI and machine learning tools for consistent high-resolution land cover mapping based on time-series NAIP imagery.

Landscape ecology·2026
Same author

Wearable, broadband auscultation patch with cantilever pressure transducer for remote healthcare monitoring.

Nature communications·2026
Same author

Compliance modulation of a soft robotic atrioventricular model of heart failure with preserved ejection fraction.

Nature communications·2026

Related Experiment Video

Updated: Sep 28, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K

Controllable high-performance liquid marble micromixer.

Nhat-Khuong Nguyen1, Pradip Singha1, Yuchen Dai1

  • 1Queensland Micro- and Nanotechnology Centre, Griffith University, 170 Kessels Road, Nathan 4111, Queensland, Australia.

Lab on a Chip
|March 28, 2022
PubMed
Summary
This summary is machine-generated.

This study introduces a new method for mixing within liquid marbles (LMs) by rotating them. This technique significantly enhances mixing efficiency and reduces reaction times, overcoming limitations of previous manual methods.

More Related Videos

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

9.1K
Microfluidic Pneumatic Cages: A Novel Approach for In-chip Crystal Trapping, Manipulation and Controlled Chemical Treatment
09:34

Microfluidic Pneumatic Cages: A Novel Approach for In-chip Crystal Trapping, Manipulation and Controlled Chemical Treatment

Published on: July 12, 2016

9.6K

Related Experiment Videos

Last Updated: Sep 28, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K
Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
10:12

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique

Published on: June 12, 2015

9.1K
Microfluidic Pneumatic Cages: A Novel Approach for In-chip Crystal Trapping, Manipulation and Controlled Chemical Treatment
09:34

Microfluidic Pneumatic Cages: A Novel Approach for In-chip Crystal Trapping, Manipulation and Controlled Chemical Treatment

Published on: July 12, 2016

9.6K

Area of Science:

  • Microfluidics
  • Materials Science
  • Chemical Engineering

Background:

  • Liquid marbles (LMs) are versatile microreactors for chemical reactions and cell culture.
  • Effective mixing is crucial for LM applications but current strategies are limited.
  • Existing methods often rely on manual, contact-based actuation, hindering precise control.

Purpose of the Study:

  • To develop an effective and controllable mixing strategy for liquid marbles.
  • To enhance the performance of liquid marble-based microreactors.
  • To overcome the limitations of existing manual mixing techniques.

Main Methods:

  • A novel manipulation scheme was developed to induce fluid motion within liquid marbles.
  • The method involves inducing controlled rotation of the liquid marble on a horizontal axis.
  • Mixing rates and reaction times were quantitatively compared to non-actuated liquid marbles.

Main Results:

  • Rotation-induced actuation significantly enhanced mixing rates by 27.6 times.
  • Reaction times were reduced by over 10 times compared to non-actuated LMs.
  • The proposed method offers a simple, continuous, precise, and controllable solution.

Conclusions:

  • Horizontal axis rotation is a highly effective strategy for mixing in liquid marbles.
  • This technique substantially improves the efficiency and speed of reactions within LMs.
  • The developed method provides a high-performance, controllable mixing solution for LM platforms.