Related Experiment Video
Updated: Sep 28, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
A case report of radiopharmaceutical needlestick injury with scintigraphic imaging and dose quantification
James Elliott1, Mariq Weatherley2
1School of Allied and Public Health Professions, Canterbury Christ Church University, North Holmes Road Campus, Canterbury Kent, CT1 1QU, UK.
Abstract:
Attention to the implications of common needle stick injuries has focused heavily on the risk of cross-infection from blood-borne pathogens. An additional risk to the nuclear medicine healthcare worker is that of subcutaneous radioactive contamination from radiopharmaceuticals. This case report provides a rare opportunity to examine the clinical and operator causes of one such event during the dispensing of 99mTc-Tetrofosmin. Contamination monitoring, scintigraphic imaging, and quantification of effective radiation dose provide the level of risk to the operator from the subcutaneous radioactive contamination. Findings demonstrated a very low dose to operator and no deterministic radiobiological effects. Delayed imaging demonstrated negligible biological clearance from the injury site. Implications of the findings for clinical practice are discussed, highlighting the need for a careful and calm approach to radiopharmacy activities.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies VII: Vascular Imaging