Related Experiment Video
Updated: Sep 28, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Multimodal Structural Analysis of the Human Aorta: From Valve to Bifurcation
Lakmini Liyanage1, Liam Musto1, Charley Budgeon1
1Department of Cardiovascular Sciences, University of Leicester and Cardiovascular Theme, NIHR Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
Objective:
The aims of the present study were to assess the relative proportion of collagen and elastin in the arterial wall and to evaluate the collagen microstructure from the aortic root to the external iliac artery.
Methods:
Arterial wall tissue samples sampled during post-mortem examination from 16 sites in 14 individuals without aneurysm disease were fixed and stained for collagen and elastin. Stained sections were imaged and analysed to calculate collagen and elastin content as a percentage of overall tissue area. Scanning electron microscopy was used to quantify the collagen microstructure at six specific arterial regions.
Results:
From the aortic root to the level of the suprarenal aorta, the percentages (area fractions) of collagen (ascending, descending, and suprarenal aorta respectively with 95% confidence interval [CI] 37.5%, 31.7 - 43.2; 38.9%, 33.1 - 44.7; 44.8%, 37.4 - 52.1) and elastin (43.0%, 37.3 - 48.8; 40.3%, 34.8 - 46.1; 32.4%, 25.2 - 39.6) in the aortic wall were similar. From the suprarenal aorta to the internal iliac arteries, the percentage of collagen increased (abdominal aorta, common and internal iliac arteries and external iliac artery respectively with 95% CI 50.6%, 42.7 - 58.7; 51.2%, 45.5 - 56.9; 49.2%, 42.0 - 56.4) reaching a double percentage for elastin (23.6%, 15.7 - 31.6; 20.8%, 15.1 - 26.5; 22.2%, 14.9 - 29.5). Mean collagen fibre diameter (MFD) and average segment length (ASL) were significantly larger in the external iliac artery (MFD 6.03, 95% CI 5.95 - 6.11; ASL 22.21, 95% CI 20.80 - 23.61) than in the ascending aorta (MFD 5.81, 5.72 - 5.89; ASL 19.47, 18.07 - 20.88) and the abdominal aorta (MFD 5.92, 5.84 - 6.00; ASL 21.10, 19.69 - 22.50).
Conclusion:
In subjects lacking aneurysmal disease, the aorta and iliac arteries are not structurally uniform along their length. There is an increase in collagen percentage and decrease in elastin percentage progressing distally along the aorta. Mean collagen fibre diameter and average segment length are larger in the external iliac artery, compared with the ascending and the abdominal aorta.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Thoracic Aorta
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
Structure of Blood Vessels
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Anatomy of Blood Vessels
Arteries
Arteries circulate oxygenated blood from the heart, except the pulmonary artery, which transports deoxygenated blood to the lungs. Large arteries, such as the aorta,...
Overview of Systemic Arteries
Systemic circulation is the part of the cardiovascular system that carries oxygenated blood away from the heart to the body's tissues and returns deoxygenated blood back to the...