A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
A Three-Dimensional-Printed Recyclable, Flexible, and Wearable Device for Visualized UV, Temperature, and Sweat pH
Yang Liu1,2, Haofei Li1,3, Qi Feng1,4
1Department of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China.
Abstract:
Wearable devices are now recognized as a powerful tool to collect physiological and environmental information in a smart, noninvasive, and real-time manner. Despite the rapid progress of wearable devices especially wearable electronic devices, there are still several challenges that limit their further development, for example, a complicated electrical signal acquisition and processing process to eliminate the interference from the surrounding signals, bulky power supply, inevitable e-waste, and environmental pollution. Herein, we report a 3D-printed recyclable, flexible, and wearable device for visualized UV, temperature, and sweat pH sensing. Compared with wearable electronic devices, our visualized wearable device senses environmental (UV light, ambient temperature), biophysical (skin temperature), and biochemical (sweat pH) signals via stimuli-responsive color change, which does not require complicated electronic circuit design/assembly, time-consuming data processing and additional power source. In addition, this visualized wearable device is fabricated via a 3D support bath printing technology by printing UV-, temperature-, and sweat pH-sensing inks containing photochromic, thermochromic, and pH-chromic materials, respectively, into/onto sustainable starch solution, resulting in a multi-functional, recyclable, and flexible sensing device with high reproducibility. Our results reveal that UV light intensities under sunlight (0-2500 μW/cm2), ambient, and skin temperatures (0-38 °C) as well as sweat pH (4.0-7.0) can be successfully monitored.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...