Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
The impact of a novel medication scanner on administration errors in the hospital setting: a before and after
Clare L Tolley1,2, Neil W Watson3, Andrew Heed3
1School of Pharmacy, Newcastle University, Newcastle Upon Tyne, UK. Clare.brown@newcastle.ac.uk.
Objective:
The medication administration process is complex and consequently prone to errors. Closed Loop Medication Administration solutions aim to improve patient safety. We assessed the impact of a novel medication scanning device (MedEye) on the rate of medication administration errors in a large UK Hospital.
Methods:
We performed a feasibility before and after study on one ward at a tertiary-care teaching hospital that used a commercial electronic prescribing and medication administration system. We conducted direct observations of nursing drug administration rounds before and after the MedEye implementation. We calculated the rate and type ('timing', 'omission' or 'other' error) of medication administration errors (MAEs) before and after the MedEye implementation.
Results:
We observed a total of 1069 administrations before and 432 after the MedEye intervention was implemented. Data suggested that MedEye could support a reduction in MAEs. After adjusting for heterogeneity, we detected a decreasing effect of MedEye on overall errors (p = 0.0753). Non-timing errors ('omission' and 'other' errors) reduced from 51 (4.77%) to 11 (2.55%), a reduction of 46.5%, which had borderline significance at the 5% level, although this was lost after adjusting for confounders.
Conclusions:
This pilot study detected a decreasing effect of MedEye on overall errors and a reduction in non-timing error rates that was clinically important as such errors are more likely to be associated with harm. Further research is needed to investigate the impact on a larger sample of medications.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies IV: Magnetic Resonance Imaging
Errors occurring during blood pressure monitoring
Several factors...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...