Recurrent Retrobulbar Hemorrhage Associated With CPAP Use After Orbital Fracture Repair
Christine Ryu1, Katie Geelan-Hansen2, Rao V Chundury1
1Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska, U.S.A.
Abstract:
We present a patient who underwent orbital fracture repair complicated by retrobulbar hemorrhages twice within the first postoperative week. The suspected cause is continuous positive airway pressure (CPAP) use with inappropriate patient-modified settings. The most likely mechanism of action was venous congestion from the extrinsic positive pressure, similar to Valsalva maneuvers increasing orbital vasculature pressure. In our patient, because his orbital blood vessels had recently been cauterized, they were too fragile to handle the engorgement and bled, leading to a retrobulbar hemorrhage. It is possible that at a lower CPAP setting, the vascular congestion would not have been as severe and caused bleeding. We recommend routinely asking patients about CPAP use before orbital surgeries and instructing patients to stop CPAP usage for 1 week after any orbital surgeries if medically cleared.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...