Related Experiment Video
Updated: Sep 28, 2025

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Standoff Detection System Using Raman Spectroscopy in the Deep-Ultraviolet Wavelength Region for the Detection of
Shuzo Eto1, Yuji Ichikawa2, Masakazu Ogita2
1133656Central Research Institute of Electric Power Industry, Yokosuka, Japan.
Abstract:
This study developed a standoff detection system for Raman spectra in the deep-ultraviolet region to facilitate remote detection of various hazardous materials. Although Raman spectroscopy can distinguish various materials, the measurement of Raman spectra through standoff detection is challenging because of the low scattering cross-section of Raman scattering. The resonance Raman scattering effect in the deep-ultraviolet wavelength region is promising in terms of enhancing the spectral intensity of Raman scattering. A catoptric light receiver system was developed to effectively collect deep-ultraviolet light via a change in the distance from the primary to secondary mirror of the telescope. The experimental results for the standoff detection indicate that the system enables the measurement of the Raman spectrum of SO2 gas, which was locally present 20 m from the system with a wavelength resolution of 0.15 nm. The gas used in this remote measurement has a relatively simple molecular structure among chemical, biological, radiological, nuclear, and explosive gases. However, the high wavelength resolution of Raman spectroscopy will enable measurement of substances with complex molecular structures, such as bacteria and explosives, without losing the detailed structure of their spectra.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
UV–Vis Spectrometers
Gas Chromatography: Types of Detectors-II
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

