Related Experiment Video
Updated: Sep 28, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Congenital cataract surgery: long-term refractive outcomes of a new intraocular lens power correction formula
Romain Touzé1, Pascal Dureau1, Catherine Edelson1
1Pediatric Ophthalmology Department, Adolphe de Rothschild Foundation Hospital, Paris, France.
Purpose:
The final refraction after intraocular lens (IOL) implantation remains a challenge in the management of paediatric cataracts. No consensual guidelines exist for the choice of IOL power. The aim of this study was to validate a method of IOL power calculation by evaluating the final refractive error in all patients with IOL implantation operated at our institution.
Methods:
We retrospectively studied all children under 7 years of age who underwent cataract surgery with IOL implantation at our institution between 2010 and 2015. Intraocular lens (IOL) power was calculated as follows: After B-scan determination of the emmetropic IOL power, a reduction of 40%, 35%, 30%, 25%, 20%, 15%, 10% and 5% was applied to children 0-3, 3-6, 6-12, 12-18, 18-24, 24-30, 30-36, 36-48 months, respectively. The following data were collected: follow-up, age at surgery, uni- or bilaterality, implanted IOL power and final refraction.
Results:
During this period, 81 children (125 eyes) met the inclusion criteria with a median follow-up of 60 months (36-97). The median age at surgery was 6.61 months (0.76-48). We included 52 children with bilateral cataract (96 eyes) and 29 children with unilateral cataract (29 eyes). The mean implanted IOL power was 23.3 ± 4.6 diopters (D). The mean spherical equivalent at last follow-up was 0.07 ± 3.5 D.
Conclusion:
Our undercorrection formula for IOL implantation after congenital cataract surgery leads to long-term refractive results globally close to emmetropia.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview