Related Experiment Video
Updated: Sep 28, 2025

10:35
Best Current Practice for Obtaining High Quality EEG Data During Simultaneous fMRI
Published on: June 3, 2013
32.9K
EEG-fMRI: Ballistocardiogram Artifact Reduction by Surrogate Method for Improved Source Localization
Mateusz Rusiniak1, Harald Bornfleth1, Jae-Hyun Cho1
1Research Department, BESA GmbH, Gräfelfing, Germany.
Frontiers in Neuroscience
|April 1, 2022
Summary
New surrogate source models significantly improve simultaneous EEG-fMRI analysis by effectively removing ballistocardiogram (BCG) artifacts. These methods, principal components analysis (PCA-S) and independent components analysis (ICA-S), minimize distortion of brain signals compared to existing techniques.
Area of Science:
- Neuroscience
- Biomedical Engineering
- Signal Processing
Background:
- Simultaneous electroencephalography-functional magnetic resonance imaging (EEG-fMRI) offers rich insights into brain activity but is challenged by artifacts.
- The ballistocardiogram (BCG) artifact is particularly difficult to remove without compromising neural signal integrity.
- Effective artifact removal is crucial for accurate analysis of simultaneous EEG-fMRI data.
Purpose of the Study:
- To evaluate surrogate source models for separating BCG artifacts from neural signals in EEG-fMRI recordings.
- To compare the efficacy of principal components analysis (PCA-S) and independent components analysis (ICA-S) against established BCG removal methods.
- To assess the impact of artifact removal methods on electroencephalography (EEG) event-related potential (ERP) and source localization analyses.
Main Methods:
- Developed and applied surrogate source models (PCA-S and ICA-S) to separate artifactual signals.
- Compared PCA-S and ICA-S with Blind Source Separation (BSS), Optimal Basis Set (OBS), and OBS-ICA using resting-state EEG-fMRI data.
- Evaluated methods based on artifact threshold survival, signal-to-noise ratio (SNR), source localization error, and signal variance explained.
Main Results:
- PCA-S and ICA-S demonstrated superior performance in BCG artifact removal compared to established methods.
- Significant improvements were observed in source localization accuracy using surrogate source models.
- The PCA-S approach was successfully applied to a Berger experiment, confirming its practical utility.
Conclusions:
- Surrogate source models (PCA-S and ICA-S) offer a substantial advancement for analyzing simultaneous EEG-fMRI data.
- These methods effectively remove BCG artifacts with minimal distortion of neural signals, particularly benefiting source analysis.
- The findings suggest a new standard for artifact removal in combined EEG-fMRI research.
Keywords:
artifact removalblind source separation (BSS)independent component analysis (ICA)multimodal imagingoptimal basis set (OBS)pulse artifact (PA)simultaneous EEG and fMRIspatial filter (SF)