Bioanalysis of aminoglycosides using high-performance liquid chromatography.
Seth K Amponsah1, Joseph A Boadu2, Daniel K Dwamena1
1Department of Medical Pharmacology, University of Ghana Medical School, University of Ghana, Ghana.
ADMET & DMPK
|April 1, 2022
Summary
This review summarizes liquid chromatography methods for aminoglycoside antibiotic analysis. It highlights the evolution of detection techniques and the variability in calibration ranges, crucial for safe clinical monitoring.
Area of Science:
- Pharmacology
- Analytical Chemistry
- Biotechnology
Background:
- Aminoglycosides are broad-spectrum antibiotics essential for treating Gram-negative bacterial infections.
- Their narrow therapeutic index necessitates careful monitoring due to potential nephrotoxicity and ototoxicity.
- Accurate bioanalysis is critical for optimizing aminoglycoside therapy and patient safety.
Purpose of the Study:
- To systematically review and identify liquid chromatographic methods for aminoglycoside bioanalysis.
- To analyze trends in detection methods and analytical performance over time.
- To provide a guide for researchers and clinicians involved in aminoglycoside monitoring.
Main Methods:
- A comprehensive literature search was conducted across major scientific databases (PubMed, Science Direct, Scopus, Google Scholar).
- 71 articles published between 1977 and 2020 focusing on liquid chromatography for aminoglycoside bioanalysis were included.
- Data extraction focused on analytical techniques, detection methods, calibration ranges, and validation parameters.
Main Results:
- Reversed-phase liquid chromatography (RPLC) is the predominant technique.
- Detection methods evolved from UV/fluorescence (1977-2002) to mass spectrometry (2003-2020).
- Reported calibration ranges varied widely (0.1-0.5 ng/mL to 1250-200000 ng/mL), with high R² values (0.964-1.0) and acceptable precision (0.331%-19.76%) and recovery (61.0%-114.0%) in most studies.
Conclusions:
- Liquid chromatography, particularly RPLC, is a well-established technique for aminoglycoside bioanalysis.
- The shift towards mass spectrometry has likely improved sensitivity and specificity.
- This review provides valuable insights into method selection and validation for aminoglycoside monitoring in clinical and preclinical settings.
Related Concept Videos
Affinity Chromatography
1.5K
Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
1.5K
High-Performance Liquid Chromatography: Types of Detectors
857
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
857
Types Of Column Chromatography
11.9K
The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Gel Filtration Chromatography
When the...
11.9K