Left Atrial Appendage Occlusion Strengths and Weaknesses of the Lobe-Only Occluder Concept in Theory and in Practice
Related Experiment Video
Updated: Sep 28, 2025

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Kolja Sievert1, Lluis Asmarats2, Dabit Arzamendi3
1CardioVascular Center Frankfurt (CVC), St. Catherine Hospital, Seckbacher Landstraße 65, 60389 Frankfurt am Main, Germany.
Insights
Left atrial appendage closure prevents blood clots by sealing the heart's left atrial appendage. This review focuses on the advantages of single-lobe devices for this procedure.
Area of Science:
- Cardiology
- Medical Devices
- Thrombosis Prevention
Background:
- Left atrial appendage (LAA) closure aims to mitigate thrombosis risk, a key factor in the Virchow triad.
- Inefficient atrial contractility, common in atrial fibrillation, increases the likelihood of thrombus formation within the LAA.
- Current LAA closure devices strive for complete appendage sealing, prioritizing device stability and preventing device-related thrombosis.
Purpose of the Study:
- To review the features and benefits of single-lobe left atrial appendage closure devices.
- To compare single-lobe designs with other LAA closure device architectures.
- To highlight the potential advantages of plug-style LAA closure devices.
Main Methods:
- Review of existing literature on left atrial appendage closure devices.
- Analysis of device designs, focusing on pacifier (lobe + disk) and plug (single lobe) types.
- Evaluation of device performance metrics including sealing efficacy, stability, and thrombogenicity.
Main Results:
- Single-lobe (plug) devices offer a distinct design approach to LAA closure.
- These devices aim to achieve complete appendage occlusion.
- Potential benefits related to device stability and reduced thrombosis are explored.
Conclusions:
- Single-lobe devices represent a significant design in LAA closure technology.
- Their potential to effectively seal the LAA and minimize thrombotic risk warrants further investigation.
- The review emphasizes the unique contributions of single-lobe designs to the field of stroke prevention in atrial fibrillation.
Abstract:
Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.