Related Experiment Video
Updated: Sep 28, 2025

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
[Corneal epithelial thickness in keratoconus patients compared to healthy controls]
Larissa Lahme1, Jens Julian Storp2, Raphael Diener2
1Universitäts-Augenklinik Münster, Domagkstr. 15, 48149, Münster, Deutschland. larissa.lahme@ukmuenster.de.
Background:
In keratoconus (KC) a progressive deformation and thinning of the cornea occurs. In contrast to Scheimpflug-based examinations, optical coherence tomography (OCT) can precisely measure the corneal layers separately, allowing separate analyses of corneal epithelial and corneal stromal thicknesses.
Aim Of This Work:
The aim of this work was to analyze the corneal epithelial thickness measured by optical coherence tomography (OCT) in patients with KC in comparison to the corneal epithelial thickness in healthy subjects. The diagnostic value of the observed changes was evaluated.
Material And Methods:
In a retrospective analysis 125 eyes of patients with KC and 140 eyes of healthy subjects were included. Corneal measurements were performed by OCT (Optovue, XR-Avanti, Fremont, CA, USA). Corneal stromal thicknesses and corneal epithelial thicknesses in different locations were measured and analyzed.
Results:
There were significant differences in stromal and epithelial thickness measurements. Of the derived epithelial thickness parameters four showed a good discriminatory power between healthy controls and KC patients (area under the curve in the receiver operating characteristic analysis > 0.7).
Conclusion:
Patients with KC showed an altered epithelial thickness compared to healthy controls. The derived calculated parameters based on corneal epithelial thickness can distinguish between KC and a healthy cornea.