Related Experiment Video
Updated: Sep 28, 2025

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Evaluation the possibility of vortex-induced resonance for a multistage pressure reducing valve
Dongtao Xu1, Changrong Ge1, Ying Li1
1School of Mechanical Engineering & Automation, University of Science and Technology Liaoning, Liaoning Anshan, China.
Abstract:
A multistage pressure reducing valve is presented in this paper. The pressure reducing components are specially designed to not only control the flow rate but also effectively prevent the cavitation vibration. However, when the fluid flows through the pressure reducing components, the divergence and shedding of the vortices in the flow field seriously affect the stability of the valve and cause vortex-induced vibration. Especially, the main frequency of the vortex shedding is in the same frequency range as the modal frequency of the valve, the vortex-induced resonance of the valve occurs. It seriously affects the safety of a control system. In this paper, by monitoring the lift coefficient of the vortex cross flow in the valve, the frequency spectrum information of the lift coefficient is used as the novelty indexes to indicate vortex-induced vibration of the fluid in the valve. The main frequency and amplitude of vortex-induced vibration are obtained. The factors affecting the vortex-induced vibration of the fluid are analyzed. The results indicate that vortex-induced vibration is the most serious when the valve is opened or closed. The variation of the flow velocity and the pressure difference have obvious effects on vortex-induced vibration of the valve. The intensity of the variation affects the main frequency and amplitude of vortex-induced vibration. Using thermal-fluid-solid coupling modal analysis instead of traditional modal analysis, the modal frequency under the working state of the valve is obtained. It is compared with the main frequency of vortex shedding, and vortex-induced resonance does not occur in the multistage pressure reducing valve.
Related Concept Videos
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
Pipe Flowrate Measurement: Problem Solving
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
Rapidly Varying Flow

