Related Experiment Video
Updated: Sep 28, 2025

Fabrication and Characterization of Superconducting Resonators
Published on: May 21, 2016
Experimental investigation of supertransmission for an intrinsic localized mode in a cyclic nonlinear transmission
M Sato1, H Furusawa1, M Sakai1
1Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, Ishikawa 920-1192, Japan.
Abstract:
In this experimental study of the nonlinear loss mechanism between traveling localized excitation and the underlying extended normal mode spectrum for a 1D lattice, three types of cyclic, electric, nonlinear transmission lines (NLTLs) are used. They are nonlinear capacitive, inductive, and capacitive+inductive NLTLs. To maintain a robust, steady-state traveling intrinsic localized mode (ILM), a traveling wave driver is used. The ILM loses energy because of a resonance between it and the extended NLTL modes. A wake field excitation is detected directly from ILM velocity experiments by the decrease in ILM speed and by the observation of the wake. Its properties are quantified via a two-dimensional Fourier map in the frequency-wavenumber domain, determined from the measured spatial-time voltage pattern. Simulations support and extend these experimental findings. We find for the capacitive+inductive NLTL configuration, when the two nonlinear terms are theoretically balanced, the wake excitation is calculated to become very small, giving rise to supertransmission over an extended driving frequency range.
More Related Videos
14:18Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
09:19Fabrication and Characterization of Disordered Polymer Optical Fibers for Transverse Anderson Localization of Light
Published on: July 29, 2013
Related Concept Videos
Traveling Waves: Lossless Lines
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
Transmission Line Design Considerations
Lossless Lines
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...